Thermo King Troubleshooting

Thermo King – Liquid Leak Check Solutions

Posted on July 13, 2021 by Jack

Leak check solutions are generally acceptable in areas that are easily reached or where the air is saturated with refrigerant. However, several factors determine how…

Thermo King Troubleshooting

Thermo King – Discharge Pressure Regulator (DPR) Test

Posted on July 12, 2021 by Jack

Diagnosis Unit lacks heat/defrost capacity. Service Procedure 1. Test the pilot solenoid and 3-way valve for proper operation. 2. Check refrigerant charge. 3. Perform compressor…

Thermo King Troubleshooting

Thermo King – Gauge Removal

Posted on July 12, 2021 by Jack

Gauge Removal Preparation 1. Remove the high side gauge line from the discharge Schrader port. 2. Backseat the suction service valve and then crack open…

Thermo King Troubleshooting

Thermo King – Scroll Compressor Capacity Test

Posted on July 12, 2021 by Jack

The scroll compressor can not be pumped down to check the efficiency of the compressor. Use the following procedure. Diagnosis This procedure checks loss of…

Thermo King Troubleshooting

Thermo King – High Side Pump Down

Posted on July 12, 2021 by Jack

Diagnosis This procedure combines the functions of the 3-way Valve Heat Check and the Low Side Pump down. A high side pump down procedure will…

Thermo King Troubleshooting

Thermo King – Low Side Pump Down

Posted on July 12, 2021 by Jack

WARNING: New pump-down service techniques are required when working on scroll compressors. • When pumping down scroll compressors always operate the unit in low speed.…

Thermo King Troubleshooting

Thermo King – TherMax (Heat) Solenoid Leak Test

Posted on July 12, 2021 by Jack

Purpose: To check for a leak through the TherMax solenoid in the cool mode. Leak Test Procedure 1. Install a calibrated gauge manifold. 2. Confirm…

Thermo King Troubleshooting

Thermo King – TherMax (Heat) Solenoid Opening Test

Posted on July 12, 2021 by Jack

Purpose: To test the TherMax solenoid for opening. TherMax Solenoid Opening Test Procedure 1. Install a calibrated gauge manifold. 2. Remove the #26 wire from…

Thermo King Troubleshooting

Thermo King – Receiver Outlet Check Valve Test

Posted on July 12, 2021 by Jack

Purpose: To check for a leak through the receiver outlet check valve. 1. Install a calibrated gauge manifold. 2. Install an additional compound gauge on…

Thermo King Troubleshooting

Thermo King – Low Side Pump Down – TherMax Units

Posted on July 12, 2021 by Jack

Purpose: To test for internal high to low side leaks and to perform low side service without refrigerant loss. Low Side Pump Down Procedure 1.…

Posts navigation

Previous Page Page 1 … Page 27 Page 28 Page 29 … Page 74 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2025 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions