Thermo King Troubleshooting

Thermo King – Introduction to the TherMax System

Posted on July 12, 2021 by Jack

The Thermax system allows the complete unit charge to be available during heat. Truck units with TherMax have had some components of the standard 3-way…

Thermo King Troubleshooting

Thermo King – Heat Exchanger Test for Internal Leaks

Posted on July 12, 2021 by Jack

Purpose: To test the heat exchanger for an internal high side to low side leak. NOTE: To prevent refrigerant loss to the atmosphere, recovery equipment…

Thermo King Troubleshooting

Thermo King – Expansion Valve Check / Adjustment

Posted on July 8, 2021 by Jack

Purpose: This check confirms the expansion valve setting and operation and enables the technician to make adjustments if required. NOTE: Perform low side pumpdown, compressor…

Thermo King Troubleshooting

Thermo King – Testing the Condenser Side of the 3-way Valve

Posted on July 8, 2021 by Jack

1. Momentarily energize the pilot solenoid to shift the 3 way valve. NOTE: On late 1989 and newer units the pilot solenoid must remain energized…

Thermo King Troubleshooting

Thermo King – Testing the Condenser Check Valve

Posted on July 8, 2021July 8, 2021 by Jack

1. Front seat the condenser pressure bypass check valve. 2. Operate the unit in high speed cool and cover the condenser coil to build discharge…

Thermo King Troubleshooting

Thermo King – Combined Heating Test

Posted on July 8, 2021 by Jack

Purpose: To test the condenser check valve, the condenser side of the 3-way valve and the condenser pressure bypass check valve on units with heat…

Thermo King Troubleshooting

Thermo King – Compressor Oil Condition

Posted on July 8, 2021July 8, 2021 by Jack

Check compressor oil condition by observing its color during each major service or system repair. Test a sample of compressor oil for acid contamination. If…

Thermo King Troubleshooting

Thermo King – Compressor Oil Checks

Posted on July 8, 2021 by Jack

Purpose: To check compressor oil level, oil condition and oil pressure. Oil Level Check Procedure 1. Warm the unit evaporator by operating the unit with…

Thermo King Troubleshooting

Thermo King – Compressor Capacity Test

Posted on July 8, 2021 by Jack

Purpose: To test compressor piston reed condition, piston to cylinder clearance, piston and cylinder condition, and compressor performance capability. Preparations Before the Test 1. Ambient…

Thermo King Troubleshooting

Thermo King – Compressor Pump Down for Service

Posted on July 7, 2021July 7, 2021 by Jack

Pump down the compressor and adjust pressures slightly positive (1 to 2 psig) to perform the following service: 1. Add or remove compressor oil. 2.…

Posts navigation

Previous Page Page 1 … Page 28 Page 29 Page 30 … Page 74 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2025 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions