Thermo King Troubleshooting

Thermo King – Compressor Pump Down for Diagnosis

Posted on July 7, 2021July 7, 2021 by Jack

Purpose: To check for internal leaks through the discharge valve plates and the pilot solenoid and to perform service work on the compressor. Compressor Pump…

Thermo King Troubleshooting

Thermo King – Seal Point Elimination Procedure

Posted on July 7, 2021July 7, 2021 by Jack

Purpose: To use a process of elimination to identify an internal leak. 1. Eliminate the bypass check valve. Perform a low side pump down with…

Thermo King Troubleshooting

Thermo King – Low Side Pump Down for Service

Posted on July 7, 2021 by Jack

After performing steps #1-6 above, the following service can be performed with the low side pumped down and a slight positive pressure established. 1. Add…

Thermo King Troubleshooting

Thermo King – Low Side Pump Down for Diagnosis

Posted on July 7, 2021 by Jack

Purpose: To test for internal high to low side leaks and to perform service on the low side without refrigerant loss. Low Side Pump Down…

Thermo King Troubleshooting

Thermo King – Suction Pressure Regulator Test/ Adjustment

Posted on July 7, 2021 by Jack

Purpose: To check or adjust the suction pressure regulator setting. Test & Adjustment Procedure 1. Obtain the recommended setting from current Service Bulletins or the…

Thermo King Troubleshooting

Thermo King – Throttling Valve Adjustment

Posted on July 7, 2021 by Jack

Purpose: To properly adjust throttling valves. Adjustment Procedure 1. Pump down the compressor or the low side and adjust compressor crankcase pressures to approximately one…

Thermo King Troubleshooting

Thermo King – Throttling Valve Pressure Setting Check

Posted on July 7, 2021 by Jack

Purpose: To accurately check the pressure setting of mechanical throttling valves. Test Procedure 1. Obtain the recommended setting from current Service Bulletins or the unit…

Thermo King Troubleshooting

Thermo King – Unit Performance Field Test

Posted on July 7, 2021 by Jack

Purpose: This field test determines whether a unit is performing up to standards. To complete the test, prepare the unit, measure the temperature difference of…

Thermo King Troubleshooting

Thermo King – Adding Refrigerant by Weight to an Evacuated, Non-Operating Unit

Posted on July 7, 2021 by Jack

NOTE: The unit should be kept off when performing these procedures. 1. Install a calibrated gauge manifold. 2. Recover the refrigerant and evacuate the system.…

Thermo King Troubleshooting

Thermo King – Overcharge Test

Posted on July 7, 2021 by Jack

Purpose: To check a unit suspected to be overcharged. 1. Install a calibrated gauge manifold. 2. Operate the unit in high speed cool five minutes…

Posts navigation

Previous Page Page 1 … Page 29 Page 30 Page 31 … Page 74 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2025 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions