Thermo King Troubleshooting

Thermo King – Adding Refrigerant to a Partially Charged, Operating Unit

Posted on July 7, 2021 by Jack

Purpose: To add refrigerant to a unit low on charge. 1. Install a calibrated gauge manifold. 2. Attach the manifold service line to the refrigerant…

Thermo King Troubleshooting

Thermo King – Controlled Refrigerant Level Check

Posted on July 7, 2021 by Jack

Purpose: To check a unit for the recommended charge. 1. Install a calibrated gauge manifold. 2. Operate the unit in high speed cool. 3. Maintain…

Thermo King Troubleshooting

Thermo King – Quick Refrigerant Level Check

Posted on July 1, 2021 by Jack

Purpose: To identify units that have recently developed a leak and have lost refrigerant. 1. Operate the unit on high speed cool 5 to 10…

Thermo King Troubleshooting

Thermo King – Removing the Gauge Manifold

Posted on July 1, 2021 by Jack

Purpose: To properly remove gauges and minimize the loss of refrigerant. 1. Operate the unit in the cool mode. 2. Back seat the discharge service…

Thermo King Troubleshooting

Thermo King – Installing a Gauge Manifold without Low Loss Fittings

Posted on July 1, 2021 by Jack

Purpose: To properly install gauges without low loss fittings. 1. Remove both the discharge and suction service valve stem caps. Save and re-use the caps…

Thermo King Troubleshooting

Thermo King – Installing and Purging a Gauge Manifold with Low Loss Fittings

Posted on July 1, 2021 by Jack

Purpose: To properly install gauges with low loss fittings. 1. Remove both the discharge and suction service valve stem caps. Save and re-use the caps…

Thermo King Troubleshooting

Thermo King – Conditions That Can Cause Low Discharge Pressure

Posted on July 1, 2021 by Jack

a. Low refrigerant charge. b. Low suction pressure. c. Worn compressor. d. Cold ambient temperature. e. Incorrect refrigerant. f. Low box temperature. g. Low compressor…

Thermo King Troubleshooting

Thermo King – Conditions That Can Cause High Discharge Pressure

Posted on July 1, 2021 by Jack

a. Air or non-condensables in system. b. Restricted air flow across condenser. (Dirty condenser fins, etc.) c. A restriction in the high pressure line between…

Thermo King Troubleshooting

Thermo King – HIGH SUCTION PRESSURE – UNFROSTED LINE

Posted on July 1, 2021 by Jack

Basic Problem: High Pressure Internal Vapor Leak to Low Side a. 3-way valve evaporator seat leaks to the low side. b. Leaking bypass check valve.…

Thermo King Troubleshooting

Thermo King – HIGH SUCTION PRESSURE – FROSTED LINE

Posted on July 1, 2021 by Jack

Basic Problem: High Pressure Internal Liquid Leak to Low Side a. Poor expansion valve bulb contact with suction line or bulb not insulated with cork…

Posts navigation

Previous Page Page 1 … Page 30 Page 31 Page 32 … Page 74 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2025 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions