Evaporators

HVAC Flooded floor-type blower

Posted on January 16, 2011November 13, 2012 by admin

Gas and liquid leg shutoff Figure 10-18 illustrates a flooded floor unit suitable for operation down to ?70°F (?57°C). The gas-pressure-powered valve used in this…

Evaporators

HVAC Flooded-ceiling blower

Posted on January 16, 2011November 12, 2012 by admin

Top hot-gas feed Figure 10-16 shows a modification of the system shown in Fig. 10-15. In the system shown in Fig. 10-16, top-fed hot defrost…

Evaporators

HVAC Flooded-ceiling evaporator—liquid leg shutoff

Posted on January 16, 2011November 13, 2012 by admin

Bottom hot-gas feed Figure 10-14 illustrates a flooded-ceiling evaporator. Upon initiation of the defrost sequence, the hot gas solenoid (Number 1) is opened. Gas flows…

Evaporators

HVAC Flooded-gas leg shutoff

Posted on January 16, 2011November 13, 2012 by admin

The system shown in Fig. 10-13 is similar to that shown in Fig. 10-12. However, the liquid leg of the evaporator dumps directly into the…

Evaporators

HVAC Flooded Liquid Systems

Posted on January 16, 2011November 13, 2012 by admin

Figure 10-12 shows a flood-gas and liquid leg shutoff (top hot-gas feed) system. Here, the gas-powered valve is used on both ends of the evaporator.…

Evaporators

HVAC Direct Expansion with Top Hot-Gas Feed

Posted on January 16, 2011November 12, 2012 by admin

In the evaporator shown in Fig. 10-10, when the defrost cycle is initiated, the hot gas is introduced through the hot-gas solenoid valve to the…

Evaporators

HVAC Evaporator Defrost cycle

Posted on January 16, 2011November 13, 2012 by admin

When the three-position selector switch is turned to defrost, solenoid valve A and pilot-solenoid valve D close as hot-gas valve C and evaporator-pilot valve B…

Evaporators

HVAC Evaporator Cooling cycle

Posted on January 16, 2011November 13, 2012 by admin

During the normal cooling cycle controlled by a thermostat, as room temperature rises above the high setting on the thermostat there is a need for…

Evaporators

Valves used in direct-expansion systems

Posted on January 16, 2011November 12, 2012 by admin

The pilot solenoid (valve B) is a 1/8 in. ported solenoid valve that is direct operated and suitable as a liquid, suction, hot gas, or…

Evaporators

HVAC Direct-expansion systems

Posted on January 16, 2011November 12, 2012 by admin

Figure 10-7 shows a high temperature system [above 32°F (0°C)] with no drip-pan defrost. During the normal cooling cycle, controlled by a thermostat, the room…

Posts navigation

Previous Page Page 1 Page 2 Page 3 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2025 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions