Evaporators

HVAC Liquid-Recirculating Systems

Posted on January 16, 2011November 12, 2012 by admin

Liquid refrigerant recirculating systems are frequently fed by upward liquid flow through their evaporators. These systems are called bottomfed. This is accomplished by either mechanical…

Evaporators

HVAC Flooded floor-type blower

Posted on January 16, 2011November 13, 2012 by admin

Gas and liquid leg shutoff Figure 10-18 illustrates a flooded floor unit suitable for operation down to ?70°F (?57°C). The gas-pressure-powered valve used in this…

Evaporators

HVAC Flooded-ceiling blower

Posted on January 16, 2011November 12, 2012 by admin

Top hot-gas feed Figure 10-16 shows a modification of the system shown in Fig. 10-15. In the system shown in Fig. 10-16, top-fed hot defrost…

Evaporators

HVAC Flooded-ceiling evaporator—liquid leg shutoff

Posted on January 16, 2011November 13, 2012 by admin

Bottom hot-gas feed Figure 10-14 illustrates a flooded-ceiling evaporator. Upon initiation of the defrost sequence, the hot gas solenoid (Number 1) is opened. Gas flows…

Evaporators

HVAC Flooded-gas leg shutoff

Posted on January 16, 2011November 13, 2012 by admin

The system shown in Fig. 10-13 is similar to that shown in Fig. 10-12. However, the liquid leg of the evaporator dumps directly into the…

Evaporators

HVAC Flooded Liquid Systems

Posted on January 16, 2011November 13, 2012 by admin

Figure 10-12 shows a flood-gas and liquid leg shutoff (top hot-gas feed) system. Here, the gas-powered valve is used on both ends of the evaporator.…

Evaporators

HVAC Direct Expansion with Top Hot-Gas Feed

Posted on January 16, 2011November 12, 2012 by admin

In the evaporator shown in Fig. 10-10, when the defrost cycle is initiated, the hot gas is introduced through the hot-gas solenoid valve to the…

Evaporators

HVAC Evaporator Defrost cycle

Posted on January 16, 2011November 13, 2012 by admin

When the three-position selector switch is turned to defrost, solenoid valve A and pilot-solenoid valve D close as hot-gas valve C and evaporator-pilot valve B…

Evaporators

HVAC Evaporator Cooling cycle

Posted on January 16, 2011November 13, 2012 by admin

During the normal cooling cycle controlled by a thermostat, as room temperature rises above the high setting on the thermostat there is a need for…

Evaporators

Valves used in direct-expansion systems

Posted on January 16, 2011November 12, 2012 by admin

The pilot solenoid (valve B) is a 1/8 in. ported solenoid valve that is direct operated and suitable as a liquid, suction, hot gas, or…

Posts navigation

Previous Page Page 1 … Page 8 Page 9 Page 10 … Page 24 Next Page

Recent Posts

  • New PSH Compressor From Danfoss Helps Make Heat Pumps Viable In Colder Climates
  • Eaton Launches New Mobile Power Solutions at Work Truck Show 2024
  • How to Troubleshoot a Trane TAM9 Heat Pump and a ComfortLink II XL 1050 Thermostat
  • How to Troubleshoot and Calibrate Your Humidity Sensors
  • How A. O. Smith is Revolutionizing Water Heating with New Products at IBS 2024

Categories

  • Air Distribution
  • Air Flow
  • Automotive
  • Baxi
  • Boilers
  • Compressors
  • Condensers
  • Consideration
  • Control Devices
  • Controlling Refrigerant
  • Daikin
  • DIY
  • Electric Motors
  • Evaporators
  • Furnace
  • Goodman
  • Heat Pump
  • Instruments & Devices
  • Lennox XC25
  • News
  • Parts
  • Refrigerants
  • Refrigeration
  • Repair
  • Service
  • Service Procedures
  • Solenoids and Relays
  • Study Guide
  • Thermo King Troubleshooting
  • Troubleshooting
  • TS-200/300
  • Ventilation Requirements
© Copyright 2026 – HVAC Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy - Terms and Conditions