Thermo King Tripac Sense Voltage & Reset Switch

The Thermo King Tripac is a widely used auxiliary power unit (APU) in the trucking industry. It provides heating, cooling, and electrical power to the truck’s cabin when the main engine is turned off. One important component of the Tripac system is the Sense Voltage & Reset Switch. In this article, we will explore the functionality of this switch and its significance in maintaining the optimal performance of the Tripac unit.

Understanding the Sense Voltage & Reset Switch: The Sense Voltage & Reset Switch is a critical part of the Tripac system that helps monitor and regulate the voltage levels within the APU. It is responsible for detecting any voltage irregularities and triggering an alarm or shutdown if necessary. The switch is designed to protect the APU from potential damage caused by voltage fluctuations.

Functionality and Operation: The Sense Voltage & Reset Switch continuously monitors the voltage levels of the Tripac system. It ensures that the voltage remains within the specified range to prevent any potential harm to the APU components. If the switch detects a voltage deviation beyond the acceptable limits, it will activate an alarm or initiate a shutdown to safeguard the system.

The switch also acts as a reset mechanism. Once the voltage returns to the normal range, the switch can be manually reset to resume the operation of the Tripac unit. This feature allows for quick troubleshooting and recovery from voltage-related issues.

Common Issues and Troubleshooting:

  1. False Alarms: Sometimes, the Sense Voltage & Reset Switch may trigger false alarms due to temporary voltage fluctuations. In such cases, it is recommended to reset the switch and monitor the system for any recurring issues. If false alarms persist, it is advisable to consult a qualified technician for further investigation.
  2. Voltage Deviations: If the switch consistently detects voltage deviations beyond the acceptable range, it may indicate an underlying electrical problem. In such situations, it is crucial to inspect the electrical connections, wiring, and battery condition. Any loose connections or damaged components should be repaired or replaced promptly.
  3. Resetting the Switch: To reset the Sense Voltage & Reset Switch, locate the switch on the Tripac unit and press the reset button. Ensure that the voltage has stabilized before attempting to reset the switch. If the switch fails to reset or the voltage irregularities persist, professional assistance should be sought.

The Sense Voltage & Reset Switch plays a vital role in maintaining the optimal performance and safety of the Thermo King Tripac APU. By continuously monitoring the voltage levels and triggering alarms or shutdowns when necessary, it helps protect the system from potential damage. Understanding the functionality of this switch and following proper troubleshooting procedures can ensure the reliable operation of the Tripac unit. If you encounter persistent voltage-related issues, it is always recommended to consult a qualified technician for assistance.